Change-over Inline Oil Filter (SDFLND)---DIN 24550----up to 400 L/min---up to 63bar---material:aluminum1. TechnicalSpecifications1.1 Filter HousingConstructionThe filter housingsare designed in accordance with international regulations. They consist of afilter head with built-in change-over valve and screw-in filter bowls.Standard equipment:* without bypass valve* connection for a clogging indicator* oil drain plug (FLND 160 to 400)1.2 FilterElementsMax.Allowable D.P.:BN/HC:20bar; W/HC: 20bar 2. DescriptionMounting as inline oil filterTemperature range - 30 ℃ ~ + 100 ℃Pressure setting of clogging indicator △ Pa= 5bar-0.5bar (others on request)Cracking pressure of bypass valve △ Po=7bar±0.5bar (others on request)Seals NBR(=Perbunan) /Nitrile Butadiene Rubber3. Notes* Filterhousings must be earthed.* Whenusing electrical clogging indicators, the electrical power supply to the systemmust be switched off before removing the clogging indicator connector.* Filterswith switching valve are designed to have a permissible leakage depending onthe operating medium.4. ApplicationIt can be used for mineral oils, lubricationoils, non-flam fluids, synthetic and rapidly biodegradable fluids.5. Photos
https://www.shengdafiltration.com/inline-filter/